Screw Pile Drive Comparison Chart

Use this chart to compare Rev-Pile's screw pile / helical pile drive families by torque, hydraulic pressure, flow and output interface. It is a starting point for equipment selection—not a substitute for the pile manufacturer's installation limits or project engineering.

Fastest path: if you know your machine model but not the hydraulic or torque requirements, send us the machine and application.

Find Equipment for My Machine

Screw Pile Drive Comparison

Drive Torque Pressure Flow Output Configuration Notes
HH-6K Handheld 6,528 FT-LBS theoretical / 4,765 FT-LBS expected @ 2,100 PSI 2,100 PSI max 15 GPM max 2" Hex Handheld only; not for machine mounting
MM-10K Handheld 10,478 FT-LBS theoretical / 8,040 FT-LBS expected @ 3,000 PSI 3,000 PSI max 18.5 GPM max 2.5" Hex - Short Portable / confined-access configuration
MM-10K 10,478 FT-LBS nominal @ 3,000 PSI 3,000 PSI 18.5 GPM max 2.5" Hex - Short Standard hood, gimbal, mini-loader and other machine-mount options
12 ALS / ADS 12,445 FT-LBS @ 3,000 PSI (ALS) / 11,542 FT-LBS @ 3,500 PSI (ADS) 3,000 or 3,500 PSI 55 GPM max @ 1,800 PSI 2.5" Hex Standard hood or gimbal; HALO options
16 ALS / ADS 17,334 FT-LBS @ 3,000 PSI (ALS) / 16,111 FT-LBS @ 3,500 PSI (ADS) 3,000 or 3,500 PSI 61 GPM max @ 1,800 PSI 3.0" Hex Standard hood, gimbal and heavy-duty gimbal options
20 ALS / ADS 21,012 FT-LBS @ 3,000 PSI (ALS) / 19,488 FT-LBS @ 3,500 PSI (ADS) 3,000 or 3,500 PSI 61 GPM max @ 1,800 PSI 100 mm Square Standard hood or gimbal; HALO options
25 ALS / ADS 26,375 FT-LBS @ 3,000 PSI (ALS) / 24,514 FT-LBS @ 3,500 PSI (ADS) 3,000 or 3,500 PSI 61 GPM max @ 1,800 PSI 100 mm Square Standard hood or gimbal; HALO options
30 ADS 30,771 FT-LBS nominal 3,500 PSI @ 33 GPM 61 GPM max @ 1,800 PSI 100 mm Square Standard hood or gimbal; HALO options
SD95 2-Speed 67,675 FT-LBS standard / 69,244 FT-LBS HPT 3,500 PSI standard / up to 5,000 PSI HPT Up to 100 GPM Heavy-duty system High-torque two-speed drive family

How to Use the Chart

Start with required installation torque and the pile system's maximum allowable installation torque. Then verify the carrier's auxiliary pressure and flow, the machine/coupler, mounting arrangement and required output interface.

Pressure and flow should not be considered independently. Pressure determines torque potential within a particular motor/gearbox configuration, while flow primarily affects rotational speed. The ALS and ADS versions use different hydraulic configurations, so a higher system pressure does not automatically mean the higher-torque version.

Complete the Installation System

The hydraulic drive is only one part of the installation setup. A complete system may also require:

See the Complete Screw Pile Installation System Guide

Need Help Choosing?

Send Rev-Pile your carrier make/model, GPM, PSI, pile system and required installation torque. If you do not know all of those values, send what you have and we can help identify the missing equipment-selection information.

Get an Equipment Recommendation